Communication Protocol between UART8 and the
Controller
Ver:02
Network
communicatio
n protocol of
UART8
Baud Rate: 38400 9N1
Communication Mode: RS 485 half duplex
Contr
oller
to
depen
dent
machi
ne(U
ART8
)
Controller gives out reset
instruction:
FF 02 03 00
The instruction about the
Controller inquiries the
model number of the
network equipment:
FF 02 03 01 ID 00
Controller delivers message
to UART8:(send out the data
by UART8)
ID Data Length (Byte) Passage (Byte) Baud rate(Byte) Data.
Refer to the following data definition form
ID is 0x03 Hex~ 0xFE Hex (9N1)
No message from the
Controller to UART8:(free):
ID 00
Depe
ndent
machi
ne
(UAR
T8) to
Contr
oller:
The return model of UART8:
02 09 05 00 00 43 4C 43 49 2D 38
Concrete model, for example ,the above one is CLCI-8
Instruction
0x09 is the length of the instruction, refers to the
number of the bytes afterwards.
0x02 is the instruction
Power controller has some
message to Controller:
(When the data mode
delivered by Controller
has some mistakes or
the receiving buffer area
was covered.)
02 01 'E'
E: Error
0x01 is the length of the instruction
0x02 is the instruction
No message from the power
controller to Controller:
02 00
Instructions:
1. The commands delivered by Controller to network equipment are separated by 00 Hex,that is,it works as
the ending of the former command and the beginning of the following one.00 Hex is the data format of nine,
and the ninth one is zero; When receive this data, the indicating needle will do a zero clearing.
2. The bytes of the commands are all 9N1,and the ninth one is 1,refer to the above when come in front of
concrete commands.
3. The commands listed above are all sent out in reverse-code manner.
The
communicatio
n protocol of
UART8RS-23
2
Input Baud
Rate:
38400 8N1
Communicatio
n Mode:
RS-232 half duplex
Communication Protocol:
0x1B 0x43 0xDD 0x0D 0x0A Passage (BYTE) Baud Rate (BYTE) Date Length (Int)H (int)L Data.
Beginning instruction refer to the following data definition form
Data
Passage (BYTE)